Proven Seven-Air System units comply with the new “SWKI RE200-02” guideline
Legionella are bacteria found in water and damp environments. They multiply particularly rapidly in water systems where water temperatures range between 25°C and 45°C. This can pose a health risk.
Adiabatic cooling methods are of particular importance in this context. These are systems that cool by evaporating water. If these systems rely on the principle of recirculating water, the risk of Legionella proliferation in the humidifier water increases significantly, as the high water temperatures promote growth.
Cooling units with a recirculating water loop pose an increased risk for Legionella proliferation.
For this reason, Seven-Air has relied exclusively on controlled spraying with fresh water in its HYBRICOOL and RECOCOOL systems for decades. In doing so, the requirements of the “SWKI RE200-02” guideline are taken into account and fully met.
HYBRICOOL - Hybrid Recooling System for Refrigeration Systems
The HYBRICOOL is designed to cool a liquid medium using ambient air and water. Seven-Air’s hybrid recooling system always consists, as standard, of one or more heat exchangers as well as variable-speed radial or axial fans. A spray bar with jet nozzles ensures that the heat exchangers are wetted.
RECOCOOL - Adiabatic Supply Air Cooling in Ventilation Systems
RECOCOOL is a ready-to-connect system air conditioning unit. A mobile nozzle cart sprays water onto the exhaust air side of the plate heat exchanger; this water is carried by the airflow through the one-piece corrugated plates to all parts of the heat exchanger. As the water evaporates, heat is continuously extracted from the exhaust air and the heat exchanger surface. The warm outside air flows through the plate heat exchanger on the opposite side and is cooled. This supply air cooling allows for savings in electrical cooling energy or eliminates the need for a cooling system altogether.
In the HYBRICOOL and RECOCOOL systems, the treated spray water required for the evaporation process is drawn from the fresh water supply and sprayed onto the heat exchanger fins via the spray nozzles using mains water pressure. The residual water is discharged directly into the drain. A recirculation loop is not required. Therefore, a collection tank with a water sump and circulation pump is not needed.
Thanks to their operation using only fresh water and the integrated hygiene control system designed to prevent stagnant incoming water, the “HYBRICOOL” and “RECOCOOL” eliminate the risk of Legionella.
Advantages of the HYBRICOOL and RECOCOOL:
- No recirculating water --> Eliminates the risk of Legionella
Reduced maintenance requirements --> Savings on maintenance costs
Less fouling of the heat exchanger fins --> Consistent efficiency
--> Lower energy costs